CONTROL SYSTEM
TNV Application Manual
2-23
Table 2-7 Requirements of user-selected electrical parts
Part name
E-ECU pin No.
Requirements
Stop switch
E15
Contact
Normally closed (b-contact)
Max.
current 12 Vdc/20 mA or higher
Min.
current 12 Vdc/10 mA or lower
Load factor monitor
E32
Resistive load
Pulled up to 12 Vdc
Max. current
12 Vdc/200 mA or lower
ON voltage
1.5 V Max.
OFF voltage
Power supply voltage
Speed monitor
E22
Eco-mode lamp
(Speed change indication lamp)
E2
Lamp load
12 Vdc-3.4 W Max.
Rush current
12 Vdc/3 A-10ms Max.
Block heater relay
Contact
Normally open (a-contact)
Rated voltage
12 Vdc
Rated load current 100V: 115 Vac/4 A Min., continuous
200V: 210 Vac/2 A Min., continuous
Coil current
12 Vdc/300 mA Max.
Coil inductance
200 mH Max.
Switching durability 10
6
times or more
Other features must be compliant with applicable specifications.
When the block heater is connected to the commercial
power supply, observe standards and regulations
concerning the dielectric withstand voltage and insulation
resistance of relay contacts.
Droop switch
E24
Contact
Normally open (a-contact)
Max. current
12 Vdc/20 mA or higher
Min. current
12 Vdc/10 mA or lower
Rmax1 switch
E13
Rmax2 switch
E14
Speed1 switch
E9
Speed2 switch
E17
Reverse droop switch
E5
Speed selection enable switch
E6
00_Electronic_Control_System.book 23 ページ 2006年5月29日 月曜日 午後2時12分
Summary of Contents for Yanmar 3TNV82A-B
Page 95: ...CONTROL SYSTEM 2 76 TNV Application Manual 00_Electronic_Control_System book 76...
Page 96: ...Appendix Standard harness 1 00_ _E fm 1...
Page 97: ...Appendix Standard harness 2 00_ _E fm 2...
Page 98: ...TNV Series service tool Operation Manual...
Page 132: ...32 7 Main Menu Figure 7 15 Data Logging Data Monitor Screen...
Page 145: ...7 Main Menu 45 Figure 7 27 System Installation Configuration Screen...