―― 7. Main Menu
7.4.3 Digital Output Test 【Mechanic Function】
This function is used to check the operation of output devices after troubleshooting and repair. You can turn
ON/OFF contacts forcibly only when the engine is stopped. When the screen is selected, the screen display is
automatically refreshed at intervals of 2 seconds by default.
1)Operation tool bar
①
:Prints a hardcopy of the screen.
②
:Saves the screen in BMP format.
③
:Saves data on the screen in a CSV file.
④
:Refreshes the current value data.
⑤
:Refreshes the current value data continuously.(At intervals of 2 seconds)
⑥
:Stops continuous refreshing.
2)Main view
⑦
Manual
:Displays whether manual control mode is enabled. You can change the mode.
・To change the mode, click the checkbox. The checkmark indicates manual mode.
・To return to auto control mode, clear the checkbox.
⑧
Description
:Displays output device names.
⑨
On/Off
:Displays current values and changed values(painted in light blue).
・Clicking this field reverses the output status.
・If the password(level 2)has not been entered, you need to enter it.
・The password is valid until you exits from this submenu.
・If change is not allowed, the item is painted in red.
・Outputs for which active ON/OFF control is prohibited(main relay, etc)are defined for the system.
⑩
Notes
:Field for notes.
Summary of Contents for Yanmar 3TNV82A-B
Page 95: ...CONTROL SYSTEM 2 76 TNV Application Manual 00_Electronic_Control_System book 76...
Page 96: ...Appendix Standard harness 1 00_ _E fm 1...
Page 97: ...Appendix Standard harness 2 00_ _E fm 2...
Page 98: ...TNV Series service tool Operation Manual...
Page 132: ...32 7 Main Menu Figure 7 15 Data Logging Data Monitor Screen...
Page 145: ...7 Main Menu 45 Figure 7 27 System Installation Configuration Screen...