7-97
1.
1. WHEN STARTING SWITCH IS TURNED ON, CLUSTER
WHEN STARTING SWITCH IS TURNED ON, CLUSTER AND MONITOR
AND MONITOR LAMP DOES NOT
LAMP DOES NOT
LIGHT UP
LIGHT UP
·
Before carrying out below procedure, check all the related connectors are properly inserted and the
fuse No.1
7
is not blown out and ON/OFF of bulb.
·
After checking, connect the disconnected connectors again immediately unless otherwise
specified.
GROUP 6 TROUBLESHOOTING
GROUP 6 TROUBLESHOOTING
YES
NO
1
CN-56
CLUSTER
FUSE [CN-37]
No.17
1
CN-57
MONITOR
Check voltage
760F7EL24
YES
20 ~ 30 V
NO
0 V
Cause
Remedy
Defective cluster
Defective monitor
Disconnection in
wiring harness or
poor contact
between CN-56
(1), CN-57 (1)
and fuse No. 17
Replace
Replace
Repair or
replace
(after clean)
Check voltage
between CN-56
(1), CN-57(1) and
chassis
Summary of Contents for HL955
Page 557: ...7 6 MEMORANDUM MEMORANDUM ...