Time specification
T1 : 0.5sec.
T2 : Max 2sec.
T3 : 1.0±0.2sec.
2. Disarm function
Disarming can be performed while the alarm is armed, or alarming, or after alarming. The alarm can be
disarmed by the following methods:
In the disarm state the visible and audible warnings are disabled and start is enabled.
In the disarm state, if TX key unlock command is received, then the hazard lamps shall be flashed twice for
period of cycle 1 sec, 50% duty rate.
Disarm state cannot be reached using the door locks by key.
Time specification
T1, T2 : 0.5±0.1sec.
A. Pressing the unlock button on the TX key. The hazard lamps shall be flashed twice for 1sec period (of
cycle), 50% duty rate.
B. If door warning switch is on, IGN1 and IGN2 are on in arm state, then arm state should be immediately
cancelled. This means that the driveris inside the vehicle before pushing TX lock, so system should not
arm.
3. Alarm function
(1) European countries
Once armed, should any door, hood or the tailgate be opened, then:
The alarm is given in the case where a door is opened with a key.
Time specification
T1 : 27±2 sec.
T2 : 0.5±0.1 sec.
A. Start relay drive output is disabled, so starting is inhibited.
B. Audible (horn) and visual (hazard lamp) warnings are issued, for 27seconds duration. The horn
warning is continuously occurring in this period.The hazard lamps operate with 1 sec period, 50 % duty
rate.
(2) Non European countries
Page 8 of 11
24.04.2008
http://www.hmaservice.com/viewer/content.asp?IsPrint=true&imgnum=1&print_title...