CHARGING SYSTEM TEST RESULTS
RESULT ON PRINTER
REMEDY
Charging system normal/Diode
ripple normal
Charging system is normal
No charging voltage
Generator does not supply charging current to battery
→
Check belts, connection between generator and battery
Replace belts or cable or generator as necessary
Low charging voltage
Generator does not supply charging current to battery and electrical load to
system fully
→
Check belts and generator and replace as necessary
High charging voltage
The voltage from generator to battery is higher than normal limit during
voltage regulating.
→
Check connection and ground and replace regulator as necessary
Excess ripple detected
One or more diodes in the generator is not functioning properly
→
Check generator mounting and belts and replace as necessary