TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Air conditioning
System > A.Q.S (Air Quality Sensor) > Description and Operation, TIBURON(GK) > 2003 > G 2.7 V6
DOHC > Heating,Ventilation, Air Conditioning > Air conditioning System > A.Q.S (Air Quality Sensor) >
Description and Operation
DESCRIPTION
1. The A.Q.S. sensor, located at the center support in front of the engine radiator, detects hazardous elements in
ambient air and provides output signals to the control module.
2. It will detect sulfurous acid gas, carbon dioxide, carbon monoxide, hydrocarbon and allergen.
3. Sensitivity of used gas sensor
A. Sensitivity at NO2 0.3PPM : more than 2.8
B. Sensitivity at gasoline 10PPM : less than 0.45
4. Delay time
SENSOR OUTPUT
A. ON time (on) : 5sec.
B. OFF time (off) : 0sec.
Condition
Resistance
Normal condition
5V
Hazardous gas detection
0V
Page 1 of 1