3. If the low-pressure does not reach more than 93.3 kPa (700 mmHg, 27.6 in.Hg) in 15 minutes, there is probably a leak in
the system. Partially charge the system, and check for leaks.
SYSTEM CHARGING
• Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.
• Be careful when connecting service equipment.
• Do not breathe refrigerant or vapor.
1. Connect a R-134a refrigerant recover/recycling/charging station(A) to the high-pressure service port(B) and the low-
pressure service port(C), as shown, following the equipment manufacture s instructions.
2. Add the same amount of new refrigerant oil to the system that was removed during recovery. Use only FD46XG (PAG)
refrigerant oil
3. Carge the system with the specified amount of R-134a refrigerant. Do not overcharge the system; the compressor will be
damaged.
Refrigerant capacity : 600 ± 25g
Page 7 of 7
24.04.2008
http://www.hmaservice.com/viewer/content.asp?IsPrint=true&imgnum=1&print_title...