MAINTeNANCe AND RePAIR
5-8
powermax
65/85
Operator Manual
Fault
code
Description
Power
leD
Fault
leD
Fault
icon
Solutions
0-50
Retaining cap off
On
On
• Turn OFF the power
supply. Verify that the
consumables are installed
and restart the power
supply.
• If the consumables appear
to be installed correctly,
the torch may be damaged.
Contact your Hypertherm
distributor or authorized
repair facility.
0-51
Start/trigger signal on at
power up
This situation indicates
that the power supply is
receiving a start signal. It
is sometimes referred to
as a “stuck start.”
On
On
• If the power supply is
turned on while the
torch trigger is pressed,
the system is disabled.
Release the trigger and
recycle the power switch.