TORCH SeTUP
powermax
65/85
Operator Manual
3-41
FineCut
Air flow rate - slpm/scfh
Mild Steel
Hot
155 / 330
Cold
215 / 460
Metric
Material
Thickness Amps
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
A
mm
mm
%
seconds (mm/min)
Volts
(mm/min)
Volts
0.5
40
1.5
3.8
250
0
8250
78
12700
80
0.6
8250
78
12700
81
0.8
0.1
8250
78
12700
80
1
45
0.2
8250
78
12700
82
1.5
0.4
6400
78
8500
81
2
5250
82
6250
81
3
0.5
2750
83
3650
81
4
0.6
1900
84
2450
81
english
Material
Thickness Amps
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
A
in
in
%
seconds
ipm
Volts
ipm
Volts
26GA
40
0.06
0.15 250
0.0
325
78
500
80
24GA
325
78
500
81
22GA
0.1
325
78
500
80
20GA
325
78
500
82
18GA
45
0.2
325
78
440
81
16GA
0.4
250
78
330
81
14GA
220
82
260
81
12GA
0.5
120
83
160
81
10GA
95
84
124
81
Summary of Contents for Powermax 65
Page 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Page 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Page 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Page 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...