MAINTeNANCe AND RePAIR
powermax
65/85
Operator Manual
5-9
Fault
code
Description
Power
leD
Fault
leD
Fault
icon
Solutions
0-52
Torch not connected
On
On
• Plug a torch lead into the
FastConnect receptacle
on the front of the power
supply and recycle the
power switch.
0-60
AC input voltage error
On
On
• Phase loss: Check all input
phases and fuses.
• Over voltage: Check the
line, decrease the voltage.
• Under voltage: Check the
line, increase the voltage.
0-61
AC input unstable:
Shutdown
On
On
• The incoming line current
is unstable. Power down
and correct the line
problem before continuing.
0-98
Internal communication
failure
On
On
• Power down, wait 20
seconds, power up.
• A qualified service
technician must open the
power supply case and
check the ribbon cable
between the control board
and the DSP board.
0-99
System hardware fault —
service required
Indicates a major fault
with the system.
On
On
• A qualified service
technician must service
the system. Contact your
distributor or authorized
repair facility.