TORCH SeTUP
powermax
65/85
Operator Manual
3-35
65A Shielded
Air flow rate - slpm/scfh
Aluminum
Hot
160 / 340
Cold
220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds (mm/min)
Volts
(mm/min)
Volts
2
1.5
3.8
250
0.1
8800
121
12800
122
3
0.2
7400
124
11000
123
4
0.5
6000
126
9150
124
6
3200
130
5500
127
8
0.7
1950
133
3450
129
10
4.5
300
1200
136
2050
130
12
1.2
1000
138
1650
132
16
Edge Start
650
143
1000
134
20
380
147
700
137
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
1/16 in
0.06
0.15
250
0.1
365
121
535
121
1/8 in
280
124
420
123
1/4 in
0.5
105
131
190
127
3/8 in
0.18
300
0.7
50
135
85
130
1/2 in
1.2
35
139
60
133
5/8 in
Edge Start
26
143
40
134
3/4 in
16
146
30
136
Summary of Contents for Powermax 65