SPeCIFICATIONS
1-6
powermax
65/85
Operator Manual
Powermax65 power supply ratings
Rated open-circuit voltage (U
0
)
CSA, 1-phase, 3-phase
CE, 3-phase
CSA 296 VDC
CE 270 VDC
Output characteristic
1
Drooping
Rated output current (I
2
)
20 – 65 A
Rated output voltage (U
2
)
139 VDC
Duty cycle at 40° C (104° F)
(See data plate on power supply
for more information on duty
cycle.)
CSA
CE
50% @ 65 A, 230 – 600 V, 1/3 PH
40% @ 65 A, 200 – 208 V, 1/3 PH
100% @ 46 A, 230 – 600 V, 1/3 PH
50% @ 65 A, 380/400 V, 3 PH
100% @ 46 A, 380/400 V, 3 PH
Operating temperature
14° to 104° F (-10° to 40° C)
Storage temperature
-13° to 131° F (-25° to 55° C)
Power factor
200 – 480 V CSA, 1-phase
200 – 600 V CSA, 3-phase
380/400 V CE, 3-phase
0.99 – 0.97
0.94 – 0.73
0.94
R
sce
– Short Circuit Ratio (CE models only)
U
1
– Volts AC rms, 3PH
R
sce
400 VAC
225.7
EMC classification CISPR 11 (CE models only)
4
Class A
Input voltage (U
1
)/ Input
current (I
1
) at rated output (U
2
MAX
, I
2 MAX
) (See Section 2,
Power Supply Setup
for more
information.)
CSA
CE
2,3
200/208/240/480 V, 1 PH, 50/60 Hz
52/50/44/22 A
200/208/240/480/600 V, 3 PH, 50/60 Hz
32/31/27/13/13 A
380/400 V, 3 PH, 50/60 Hz
15.5/15 A
Gas type
Air
Nitrogen
Gas quality
Clean, dry, oil-free per
ISO 8573-1 Class 1.2.2
99.95% pure
Recommended gas inlet flow
rate/pressure
Cutting: 400 scfh , 6.7 scfm (190 slpm) @ 85 psi (5.9 bar)
Gouging: 450 scfh, 7.5 scfm (210 slpm) @ 70 psi (4.8 bar)
Summary of Contents for Powermax 65
Page 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Page 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Page 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Page 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...