TORCH SeTUP
3-50
powermax
65/85
Operator Manual
65A Unshielded
Air flow rate - slpm/scfh
Aluminum
Hot
160 / 340
Cold
220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
2
2.0
5.0
250
0.1
7750
123
14200
123
3
0.2
6550
124
12000
123
4
0.5
5400
125
9500
123
6
3000
127
4850
124
8
0.7
1800
130
3000
126
10
6.0
300
0.7
1100
133
2050
127
12
Edge Start
900
135
1560
129
16
600
139
880
132
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
1/16 in
0.08
0.20
250
0.1
325
122
590
122
1/8 in
175
125
300
123
1/4 in
0.5
100
127
160
124
3/8 in
0.24
300
0.7
45
132
85
127
1/2 in
Edge Start
32
136
55
129
5/8 in
24
138
35
132
Summary of Contents for Powermax 65
Page 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Page 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Page 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Page 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...