MAINTeNANCe AND RePAIR
5-4
powermax
65/85
Operator Manual
Problem
Solutions
The ON/OFF power switch is set to
ON (I), but the power ON LED is not
illuminated.
• Verify that the power cord is plugged into the
receptacle.
• Verify that the power is ON at the main power
panel or at the line-disconnect switch box.
• Verify that the line voltage is not too low (more
than 15% below the rated voltage).
• Verify that the circuit break has not been tripped.
The arc does not transfer to the
workpiece.
• Clean the area where the work clamp contacts
the workpiece to ensure a good metal-to-metal
connection.
• Inspect the work clamp for damage and repair as
necessary.
• The pierce-height distance may be too large. Move
the torch closer to the workpiece and fire the torch
again.
basic troubleshooting
The following table provides an overview of the most common problems that can arise when using
the Powermax65 or Powermax85 and explains how to solve them.
ote:
N
Fault icons and corresponding fault codes appear in the LCD display. Refer to “Fault
codes and solutions” on page 5-6.
If you are unable to fix the problem by following this basic troubleshooting guide, or if you need
further assistance:
1. Call your Hypertherm distributor or authorized Hypertherm repair facility.
2. Call the nearest Hypertherm office listed in the front of this manual.
Summary of Contents for Powermax 65
Page 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Page 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Page 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Page 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...