MAINTeNANCe AND RePAIR
5-10
powermax
65/85
Operator Manual
Replace the gas filter element
1. Turn OFF the power, disconnect the power cord, and make sure the gas supply is
disconnected.
2. Position the rear of the power supply so the removable gas filter bowl is easily accessible.
3. Grasp the filter bowl with your right hand.
4. Push down the thumb latch and rotate the filter bowl approximately 45 degrees to the right.
5. Pull the filter bowl straight down to remove. You can see the white filter element and retaining
nut.
6. Unscrew (counterclockwise) the plastic retaining nut that secures the filter element.
7. Replace the dirty element with a new element. Reinstall (clockwise) the plastic retaining nut to
finger-tight only.
8. Insert the filter bowl with the thumb latch positioned approximately 45 degrees to the right of
center. This is the same orientation in which the filter bowl was pulled down and removed.
9. Vertically align the filter bowl (with metal guard) and firmly push the filter bowl up to the top of
the receptacle to seat the bowl. It is helpful to lift the bowl with your left index finger under the
nut on the bottom of the bowl.
10. Once the bowl is seated properly, rotate the bowl 45 degrees to the left until you hear the
thumb latch click into place.
11. Reconnect the gas supply hose to the power supply and check for leaks.
12. Reconnect the electrical power and turn ON the power switch.
Summary of Contents for Powermax 65