TORCH SeTUP
powermax
65/85
Operator Manual
3-45
85A Unshielded
Air flow rate - slpm/scfh
Stainless Steel
Hot
190 / 400
Cold
235 / 500
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds (mm/min)
Volts
(mm/min)
Volts
2
2.0
5.0
250
0.1
8550
117
14000
114
3
7000
118
12000
116
4
0.2
5600
118
9800
118
6
0.5
3400
120
5700
122
8
2250
121
3700
124
10
6.0
300
0.5
1430
123
2300
125
12
0.7
1000
129
1700
127
16
Edge Start
650
134
910
131
20
360
138
720
136
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
14GA
0.08
0.20
250
0.1
365
117
580
114
10GA
0.2
280
120
460
116
3/16 in
200
123
335
118
1/4 in
0.5
110
126
215
119
3/8 in
75
127
110
123
1/2 in
0.24
300
0.6
45
135
78
128
5/8 in
Edge Start
34
139
56
132
3/4 in
22
143
40
136
Summary of Contents for Powermax 65
Page 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Page 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Page 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Page 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...