TORCH SeTUP
3-52
powermax
65/85
Operator Manual
45A Unshielded
Air flow rate - slpm/scfh
Mild Steel
Hot
147 / 310
Cold
210 / 450
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds (mm/min)
Volts
(mm/min)
Volts
0.5
1.5
3.8
250
0.0
9000
120
12700
122
1
9000
120
12700
122
1.5
0.1
7700
120
12700
122
2
0.3
6150
119
9750
120
3
0.4
3950
121
6150
122
4
2350
123
4450
124
6
0.5
1400
126
2550
123
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
26GA
0.06
0.15
250
0.0
350
120
500
122
22GA
350
120
500
122
18GA
0.1
350
119
500
122
16GA
300
121
500
122
14GA
0.2
250
119
400
120
12GA
0.4
200
120
270
122
10GA
100
123
205
123
3/16 in
0.5
85
122
135
125
1/4 in
0.6
48
127
91
122
Summary of Contents for Powermax 65