TORCH SeTUP
3-48
powermax
65/85
Operator Manual
65A Unshielded
Air flow rate - slpm/scfh
Mild Steel
Hot
160 / 340
Cold
220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds (mm/min)
Volts
(mm/min)
Volts
2
2.0
5.0
250
0.1
6050
117
9200
116
3
0.2
5200
118
7900
117
4
0.5
4250
118
6550
117
6
2550
120
4100
119
8
1620
123
2800
120
10
6.0
300
0.7
970
127
1880
122
12
Edge Start
760
129
1400
124
16
500
134
800
128
20
280
138
560
132
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended
Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
16GA
0.08
0.20
250
0.1
255
116
385
115
10GA
190
118
290
117
3/16 in
0.2
135
119
215
118
1/4 in
0.5
90
120
145
119
3/8 in
0.24
300
0.7
40
126
78
121
1/2 in
Edge Start
27
130
50
125
5/8 in
20
134
32
128
3/4 in
13
137
22
131
Summary of Contents for Powermax 65
Page 1: ...Plasma arc cutting systems Operator Manual 806650 Revision 0 85 ...
Page 10: ...Table of Contents vi powermax65 85 Operator Manual WARRANTY vi Hypertherm ...
Page 30: ...Specifications 1 16 powermax65 85 Operator Manual ...
Page 140: ...Maintenance and Repair 5 12 powermax65 85 Operator Manual ...