Freedom 38 PPA
Service Manual
809010
103
3 – System-Level Components
Install the 480 V auxiliary outlet
1.
Run the wires through the new gasket. Make sure the wire ends are stripped clean. Do not tin the wire ends.
2.
Loosen the box terminal screws
in the interior assembly of the
receptacle until the screws start to apply pressure to the walls.
3.
Insert each of the 4 wires (red, black, white, and orange) into the proper box
terminal on the receptacle. Tighten the box terminal screws for each wire to
34.56 kg∙cm (30 in∙lb minimum).
4.
Make sure there are no stray wire strands.
5.
Set the receptacle and gasket into the front panel with the hinge facing up.
Secure using the 4 screws and torque to 34.56 kg∙cm (30 in∙lb minimum) /
46.08 kg∙cm (40 in∙lb maximum).
WH
RD
OR
BK