Freedom 38 PPA
Service Manual
809010
1 – Troubleshooting
Run a gas test
1.
Display the service screen on the plasma cutting system by simultaneously pressing the
automatic/manual
and
current/gas
mode selectors for approximately two seconds.
2.
Select the gas test field by pressing the
current/gas
mode selector until the asterisk (*) is next to the “G.”
3.
Use the adjustment knob to set the gas test field from 0 to 1.
If gas does not flow, call your Hypertherm distributor or authorized repair facility, or call the nearest Hypertherm office
listed in the front of this manual.
4.
Use the adjustment knob to set the gas test field back to 0.
5.
Simultaneously press the
automatic/manual
and
current/gas
mode selectors to exit the service screen.
CAUTION!
Point the torch away from you before performing a gas test. Always keep hands, clothes, and objects
clear of the torch tip, and never point the torch toward yourself or others.