118
Freedom 38 PPA
Service Manual
809010
4 – Plasma Components
Unfasten the plasma supply
Detach the plasma supply
This procedure is to move but not disconnect the plasma supply in order to gain access to parts otherwise inaccessible.
To fully disconnect the plasma supply from the system the power cord must be disconnected. See
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the top cover and plasma-side panel from the system. See
4.
Set the power switch
on the back of the plasma supply to OFF (
O
).
5.
Disconnect the compressed air hose
.
6.
Disconnect the machine interface (CPC) connector
.
Figure 45
7.
Remove the 2 screws that secure the rear
bracket of the plasma supply.
1
2
3
1
3
2
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...