Freedom 38 PPA
Service Manual
809010
191
6 – Air Compression Components
Replace the ball valve, elbow fitting, and elbow coupler on the separation tank
Remove the ball valve, elbow fitting, and elbow coupler on the separation tank
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Drain the air tank to release pressure. See page 61.
4.
Release pressure from the separation tank by pulling the ring on the pressure relief valve. See
5.
Remove the top cover and plasma-side panel from the system. See
6.
Drain the oil from the separation tank. See page 79.
7.
Remove the drain hose from the elbow fitting attached to the ball valve.
8.
Loosen and remove the large hose clamp around the separation tank. Remove 2 bolts and washers that secure the
tank to the system chassis. The tank can be moved to access the ball valve, elbow fitting, and elbow coupler. See
9.
Disconnect the ball valve from the two elbow fittings.
Kit number
Description
Kit: Ball valve for air compressor