2 – Routine Maintenance
Drain the condensate from the air compressor’s air/oil separation tank
1.
Make sure the system has been turned OFF for a minimum of 8 consecutive hours.
2.
Remove the service panel on the plasma side of the system.
3.
Slowly turn the valve on the bottom of the
air/oil separation tank to gradually discharge
the condensate.
4.
When you see the first traces of oil, close
the valve. The condensate exits through the
baseboard on the plasma side of the system
by the rear panel.
5.
Dispose of the condensate in compliance
with local and national regulations.
6.
Put the service panel back in place.