44
Freedom 38 PPA
Service Manual
809010
1 – Troubleshooting
Display the service screen on the plasma cutting system
You can view system information that aids troubleshooting by accessing the service screen on the plasma cutting system.
This screen displays recent fault codes, arc hours, the software version your system is running, and several additional
details. You can also run a gas test from this screen.
For example, if a fault code displays on the status screen (in the format
N-nn
) while you are operating the system, you can
check the service screen for an additional four-digit fault code (in the format
N-nn-n
). If qualified service technicians must
service the system, these four-digit fault codes help them diagnose the problem.
To display the service screen, simultaneously press the
automatic/manual
and
current/gas
mode selectors for
approximately two seconds.