9.
Loosen the top-most strain relief at the back of the AC connection cabinet
. Slowly pull the power cord’s wires
through the strain relief.
10.
Cut any cable ties that secure the power cord. Remove the power cord.
Reconnect the plasma supply power cord
1.
Make sure the system is OFF.
2.
Make sure the power switch on the back of the plasma supply is set to OFF (
O
).
3.
Route the plasma supply’s power cord wires through the top-most strain relief in the back of the AC connection
cabinet. See
in
4.
Connect the green ground wire to the ground stud in the AC connection cabinet. See
Reconnect any ground wires that were removed to access the plasma supply ground.
Secure remaining ground wires with nut.
5.
Reinstall the terminal block. See
6.
Connect the black
, red
, and white
wires as shown in
7.
Tighten the strain relief
. See
8.
Reinstall the cover on the AC connection cabinet. Secure the power cord with cable ties.
9.
Reconnect the plasma supply. See
10.
Put the system’s top cover and side panels back in place. See
11.
Reconnect the negative (-) ground cable to the battery.
8
8
5
6
7
8
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...