190
Freedom 38 PPA
Service Manual
809010
6 – Air Compression Components
Replace the pressure relief valve on the air drying filter assembly
Remove the pressure relief valve on the air drying filter assembly
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Remove the plasma-side service panel.
3.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
4.
Drain the air tank to release pressure. See page 61.
5.
Pull the ring on the air drying filter relief valve to ensure there is no pressure left.
6.
Unscrew the pressure relief valve from the air drying filter assembly.
Figure 108
Install the air pressure relief valve on the air drying filter assembly
1.
Install the new pressure relief valve. Use part number 330116 thread sealant on the relief valve. Apply a thread seal
bead on 2–3 threads. Do not over-apply to avoid air line contamination.
2.
Reconnect the battery’s negative (-) ground cable.
3.
Replace the plasma-side service panel.
Kit number
Description
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...