188
Freedom 38 PPA
Service Manual
809010
6 – Air Compression Components
10.
Disconnect the 2 hoses at the tee fitting. One hose is from the plasma power supply
and the other hose is from
the auxiliary air outlet
.
11.
Remove the tee fitting from the air drying filter assembly
.
Figure 106
12.
Remove the screws, nuts, and washers that secure the air drying filter assembly to the chassis. Remove the air drying
filter assembly from the unit. Cut any cable ties necessary to free the part.
Figure 107
5
6
7
5
6
7