2 – Routine Maintenance
3.
Replace the oil filter:
a.
Unscrew the oil filter
to remove it. See
. Dispose of the old filter in compliance with local and
national regulations.
b.
Lightly apply clean oil to the seal on the new oil filter.
c.
Screw the oil filter into place. Tighten by hand.
4.
Add new synthetic oil to the air/oil separation tank:
a.
Unscrew the fill cap
from the top of the air/oil separation tank
to remove it. See
. Set the fill cap
and its washer aside.
If needed, remove the top cover and the plasma-side panel to better access the tank.
See
b.
Pour new oil into the air/oil separation tank to the recommended fill line:
Use oil of the same type as that already in the machine. Do not mix different oil types.
Use a funnel to direct the flow of oil.
Do not exceed the maximum fill level.
Check the oil level in the air compressor
c.
Screw the fill cap and its washer back onto the top of the air/oil separation tank.
d.
Put the top cover and the plasma-side panel back in place, if you removed them. See
e.
Turn ON the system, and allow it to run until the cooler unit is hot. Shut down the system and check the oil level.
Figure 20 – Air compressor’s oil filter and air/oil separation tank
1
2
3
1
2
3
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...