194
Freedom 38 PPA
Service Manual
809010
6 – Air Compression Components
6.
Remove the 2 screws that secure the condensate valve to the bracket. Remove the valve from the bracket.
Figure 111
7.
Disconnect the 2 hoses from the elbow fittings. Remove the elbow fittings from the valve.
Install the condensate release lever
1.
Install the elbow fittings on the new lever. Use part number 330116 thread sealant. Apply a thread seal bead on 2–3
threads of each threaded connection. Do not over-apply to avoid air line contamination.
Figure 112
2.
Connect the 2 hoses to the elbow fittings. The line from the air tank connects to the machined brass fitting side of the
lever assembly
.
3.
Secure the lever assembly to the bracket using 2 screws.
4.
Replace the front panel black base plate.
5.
Replace the 2 screws behind the front panel. These are located near the 480 V auxiliary outlet electrical box. See
6.
Replace the top cover and engine-side panel. See
7.
Reconnect the negative (-) ground cable to the battery.