1 – Troubleshooting
6.
Is the automatic voltage regulator (AVR) configured
properly for this system? See page 134.
If yes, continue with the next step.
If no, examine all settings on the AVR to make
sure they are correct.
7.
Is the automatic voltage regulator (AVR) faulty?
If yes, replace the AVR. See page 133.
If no, have an Hypertherm Freedom 38 PPA
repair facility examine the generator/alternator.
If the problem is isolated to the 120 V
auxiliary outlet the transformer may be
faulty.