5 – Generator and Engine Components
Replace the automatic voltage regulator (AVR)
Remove the AVR
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the on-board plasma supply to gain access to the AVR. See
When the plasma supply is removed, you can access the AVR through that opening in
the front panel.
4.
Remove the cover panel from the AVR. See
.
5.
Remove the 4 screws that secure the AVR.
6.
Disconnect the 4 wire connections from the top of the AVR.
7.
Remove the AVR from the alternator.
Figure 57
Kit number
Description
Kit: Automatic voltage regulator (AVR) for generator/alternator, 480 VAC