114
Freedom 38 PPA
Service Manual
809010
4 – Plasma Components
Replace the air filter element and air filter bowl in the plasma supply
Remove the air filter element and air filter bowl
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Drain the air tank to release pressure. See page 61.
3.
Remove the service panel on the plasma side of the system.
4.
Disconnect the compressed air hose from the back of the plasma supply.
5.
Locate the air filter bowl in the plasma cutting system’s rear panel. The air filter element is inside the filter bowl.
The air filter bowl in your plasma supply may differ slightly from the one shown in this
picture.
Install the air filter element and air filter bowl
1.
Refer to the
Maintenance and Repair
chapter in the
Powermax125 Operator Manual
to install a new air filter element
and air filter bowl.
2.
Reconnect the compressed air hose to the back of the plasma supply.
3.
Put the service panel back in place.
Kit number
Description
Kit: Nylon air filter bowl for plasma cutting system (includes O-ring) (in rear panel recess)
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...