2 – Routine Maintenance
Service the engine air cleaner
The engine air cleaner contains 2 filters:
A
primary filter
that fits over the outlet tube, which creates a critical seal on the inside diameter of the filter
endcap
A
safety filter
that fits inside the outlet tube, which creates a critical seal on the outside diameter of the filter
endcap
Replace the safety filter every 3 air cleaner services or every 2 years, whichever interval is less.
In very dusty or dirty environments, check the primary filter approximately once every 2 weeks. Use moisture-free
compressed air to gently clean the filter, as needed. Never remove the safety filter except to install a new one.
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the service panel on the generator side of the system.
4.
Pull back the 3 clips, and remove the cover from the air cleaner. See
Figure 19
NOTICE
Replace the air cleaner filters regularly. Never run the engine when the air cleaner filters are missing
or damaged. The air cleaner filters prevent airborne debris from entering the air inlet. Dirt or other
debris that enters the engine can cause premature wear and damage to engine components that is
difficult and expensive to repair.
Cover of air cleaner
Clips
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...