170
Freedom 38 PPA
Service Manual
809010
6 – Air Compression Components
Figure 92
Install the air compressor check valve and scavenge line orifice
1.
Install the new check valve. Use part number 330116 thread sealant. Apply a thread seal bead on 2–3 threads of
each threaded connection. Do not over-apply to avoid air line contamination.
2.
Install the new scavenge line orifice. Use part number 330116 thread sealant. Apply a thread seal bead on 2–3
threads of each threaded connection. Do not over-apply to avoid air line contamination.
3.
Install the adapter on the scavenge line orifice. Use part number 330116 thread sealant. Apply a thread seal bead on
2–3 threads of each threaded connection. Do not over-apply to avoid air line contamination.
4.
Connect the oil mist line to the adapter. Clean up any oil drippings.
5.
Replace the black base plate that is below the rear panel.
6.
Reconnect the battery’s negative (-) ground cable.
7.
Run the system to distribute the oil. Set the power switch on the front panel to ON (
|
) and press the
RUN
button on
the system controller.
8.
After the unit starts up allow it to run for approximately 5 minutes.
9.
Press the OFF (
O
) button on the system controller to turn OFF the system. Make sure the power switch on the front
panel is in the OFF (
O
) position.
10.
Check for leaks and check the oil level. See
Check the oil level in the air compressor
1
2
4
3
5
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...