Freedom 38 PPA
Service Manual
809010
21
1 – Troubleshooting
Check engine and generator status
Several engine and generator status details display on the system controller’s LCD screen when the engine is running,
such as:
Total operating hours for the engine
Oil pressure
Percentage of fuel remaining
Battery voltage
Engine temperature
Total time the engine has been running since it was started
Generator current (A)
The transformer circuit breaker must be ON (
I
) in order to view the output current on the
system controller.
Generator voltage (V)
AC frequency (Hz)
You can also view the following engine status details without starting the engine by pressing the
AUTO
button:
Total operating hours for the engine
Oil pressure
Percentage of fuel remaining
Battery voltage
Engine temperature
Press the
OFF
button to exit AUTO mode.
Reset the control system
When a system fault condition occurs, the engine shuts OFF and the LED indicator on the front panel illuminates solid
red.
To clear the fault, reset the control system:
1.
Examine the LCD screen for the notification that describes why the engine shut down. Correct the fault before
continuing.
2.
Press the
OFF
button on the system controller.
3.
Press the
RUN
button to start the engine.
4.
If the control system still needs to be reset, turn the main power switch OFF (
O
) and then back ON (
I
).
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...