Electrical system / automatic lowering system
Troubleshooting
223
8
Fault
Possible causes
Remedy
Cabling / switches.
- Connections loose or dirty.
Clean the connections.
- Cable broken or terminals damaged.
Faults must be repaired by a specialist
workshop.
Lighting does not work.
- Light is faulty.
Replace the bulb.
- Connections loose or dirty.
Clean the connections.
- Short-circuit in power circuit or
interruption.
Replace the faulty LED lights and bulbs.
Faults must be repaired by a specialist
workshop.
Fault
Possible causes
Remedy
The automatic lowering system does not
work.
- The inductive sensor is badly adjusted.
Readjust the position of the sensor.
- The inductive sensor is faulty.
Have the sensor replaced in a specialist
workshop.
- The ON / OFF switch is faulty.
Have the switch replaced in a specialist
workshop.