7
Electrical system
Inspection, care and maintenance
203
Licence plate light "LED"
Pic. 83
Number plate light
1
Fastening screw
2
LED light
A faulty LED light must be completely
replaced.
Release the fastening screws
(Pic. 83 /1).
Detach the connection cable with
plug-in connector.
Replace the complete LED light
(Pic. 83 /2).
Attach the new LED lights with
fastening screws / nuts.
Connect the connection cable.
Licence plate light "Standard
Pic. 84
Number plate light 24 V
1
Fastening screw
2
Housing
3
Lens
4
Light (Soffite)
Release the fastening screws
(Pic. 84 /1).
Open the housing (Pic. 84 /2).
Replace the light (Pic. 84 /4).
Insert the lens.
Replace the housing.
Tighten the fastening screws.
W - 065
2
1
W - 066
1
2
3
4