Setting running parameters
The parameter list provided in this document includes all configurable parameters. Configurable
parameters vary depending on the device model. The actual display prevails.
Table 7-10
Parameter description
No. Parameter
Function
Value
Description
1
Offset mode
Specifies the offset
mode of the PID
module.
Disabled
Select
Disabled
if the PID module is not required.
N/PE
PID01: Select
N/PE
if the PID module is
required to use voltage output from the inductor
virtual midpoint.
SmartPID2000: Select
N/PE
if the PID module is
required to use voltage output from the power
grid.
PV/PE
PID01: Select
PV/PE
if the PID module is
required to use voltage output from the negative
PV terminal. This mode is applicable only to
Huawei SUN8000.
SmartPID2000: N/A
Automatic
PID01: For the inverter,
Automatic
indicates the
N/PE offset mode.
SmartPID2000: N/A
2
Output
enabled
Specifies whether
PID module output
is enabled.
Enable
Select
Enable
to enable the PID module output.
Disable
Select
Disable
to disable the PID module output.