SmartLogger2000
User Manual
7 WebUI
Issue 04 (2018-04-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
127
Running parameters
Figure 7-22
Running parameters
Baud rate
is set to
115200
by default, which provides optimal communications performance and
does not need to be changed.
If
Anti-crosstalk
is set to
Enable
, the inverter with a PLC STA in the SN list can access networking.
Parameters
Box-type transformer No.
and
Winding No.
can be set for the PLC CCO with
SUN2000 V100R001C72SPC100 or later versions. In multi-split transformer scenarios, specify
Winding No.
based on the actual winding number of the SmartLogger connected to the transformer.
When the box-type transformer and winding numbers of the inverter with an STA are consistent with
those of the PLC CCO, the inverter can access networking.
When the PLC CCO is SUN2000 V100R001C72SPC104 or later versions, you can set
Networking
.
When the SmartLogger communicates with the inverter over PLC, set
Networking
to
Enable
(default value).When the SmartLogger communicates with the inverter only over RS485, set
Networking
to
Disable
.