RRU3832&RRU3632
Installation Guide
8 Installing the RU
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
72
Prerequisites
The hoist clamp on the main bracket is secured properly.
Do not stand the RU upright because the RF ports cannot support the weight of the RU.
Place a foam pad or cardboard under the RU to protect the RU housing from damage
during the installation.
Context
The wall on which RUs are installed must meet the following requirements:
For each RU, the wall must be able to bear a weight four times the RU's weight and the
bolts' pulling force of 1.25 kN (281.25 lbf) vertical to the wall.
Expansion anchor bolts must be tightened to 30 N·m (265.52 lbf·in.) so that the bolts
stay secured without damaging the wall.
Procedure
Step 1
Disassemble the RU mounting brackets, as shown in
Figure 8-34
Disassembling the mounting brackets
(1) Main
bracket
(2) Square-neck
bolt
(3) Pole installation
bracket
(4) Auxiliary
bracket
(5) Flat washer
(6) Spring washer
(7) Nut
(8) Plastic cap