RRU3832&RRU3632
Installation Guide
9 Installing RU Cables
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
97
9.6 Installing an RU RF Jumper
This section describes the procedure for installing an RU RF jumper.
Procedure
Step 1
Connect the DIN male connector at one end of the RU RF jumper to the ANT port on the RU,
and use a torque wrench to tighten the connector to 25 N·m (221.27 lbf·in.), as shown in
Figure 9-13
Installing an RU RF jumper
On AC-powered electric railways, such as high speed railways, when leaky cables are
connected to RUs installed in tunnels, high-voltage-resistance DC blocks must be installed
between RU RF jumpers and the leaky cables to protect the RUs against damage.
Step 2
Link the other end of the RF jumper to the external antenna system.
Step 3
Waterproof the connectors of the RF jumper by referring to