RRU3832&RRU3632
Installation Guide
3 Information About the Installation
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
22
Figure 3-20
RU installed on a wall
Installing an RU on an IFS06
In an IFS06 scenario:
The upper and lower adjustable beams on an IFS06 can be moved up and down to fit for
heights of RUs.
The IFS06 supports at least three RUs when the ambient temperature is higher than or
equal to the lowest operating temperature of the RU and at least 5°C (41°F) lower than
the highest operating temperature of the RU. The IFS06 supports a maximum of six RUs
when the ambient temperature is higher than or equal to the lowest operating temperature
of the RU and at least 10°C (50°F) lower than the highest operating temperature of the
RU.
For details about the operating temperature of the RU, see section "Technical Specifications of RUs" in
3900 Series Base Station Technical Description
.
The mounting brackets for multiple RUs cannot be combined when the RUs are installed on
an IFS06, as shown in