RRU3832&RRU3632
Installation Guide
9 Installing RU Cables
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
103
Figure 9-20
Method for handling cord end terminals that are not in use
Step 5
Route the cables according to the instructions in
, and then use
cable ties to bind the cables.
Step 6
Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End
9.9 Opening the Cover Plate of an RU Cabling Cavity
This section describes the procedure for opening the cover plate of an RU cabling cavity.
Procedure
Step 1
Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2
Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the RU
cabling cavity, and open the cover plate, as shown in