Step 4 Remove the riser cards, PCIe cards, RAID controller cards, and supercapacitors (or
iBBUs) from the front I/O module, and place the front I/O module in an ESD bag.
For details, see
Removing a RAID Controller Card
----End
5.5.2 Installing a Front I/O Module
This topic describes how to install a front I/O module.
Scenarios
Install a front I/O module if:
●
The front I/O module has failed.
●
A riser card on the front I/O module has failed.
●
A PCIe card on the front I/O module has failed.
●
A RAID controller card on the front I/O module has failed.
●
An iBBU on the front I/O module has failed.
●
A supercapacitor on the front I/O module has failed.
●
The hard disk backplane on the front I/O module has failed.
Prerequisites
Conditions
●
You have powered off the RH8100 V3. For details, see
. Then you have removed all power cables from the server.
●
You have installed PCIe cards on the front I/O module to be installed. For
●
You have installed riser cards on the front I/O module to be installed. For
.
●
You have installed RAID controller cards on the front I/O module to be
installed. For details, see
5.5.10 Installing a RAID Controller Card
.
●
You have installed iBBUs on the front I/O module to be installed. For details,
see
●
You have installed supercapacitors on the front I/O module to be installed. For
5.5.14 Installing a Supercapacitor
Data
●
You have obtained the cabinet number and chassis number of the RH8100 V3.
●
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
●
You have determined the position on the RH8100 V3 for removing the front
I/O module.
Tools
RH8100 V3 Server
User Guide
5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19)
Copyright © Huawei Technologies Co., Ltd.
151