8. Click Save.
A dialog box is displayed, showing the following messages:
Before switching between the Single RAID and the Dual RAID, ensure that all
service systems have been properly powered on. Otherwise, the switching
fails. A misoperation of switching the RAID mode will cause data loss. Remove
the hard disks before switching, or switch the RAID mode after the service
systems have been powered on and before the operating system has started.
9. Click OK.
If the message "Operation Succeeded" is displayed, the switching is successful.
Use iBMC to power off the server.
10. On the menu bar, choose Power.
11. In the left panel, choose Power Control.
The Power Control page is displayed on the right.
12. In the Virtual Power Button area, click Power Off.
The message "Operation succeeded" is displayed.
After the server is powered off, iBMC is still available, but the CPUs and DIMMs are
powered off.
Change the RH8100 V3 operating mode. Then iBMC restarts automatically.
13. On the menu bar, choose Config.
14. In the left panel, choose System.
The System page is displayed.
15. In the Set FusionPar area, select Dual-system and enter the standby iBMC
user name and password, as shown in
.
Figure 7-36 Set FusionPar area
16. Click Save.
A dialog box is displayed, showing the following messages:
Before switching between the single-system and the dual-system, ensure that all service systems have
been properly powered off and iBMC is not being upgraded. Are you sure to perform the switching? If
the switching is successful, iBMC will restart. (If the iBMC or CPLD versions differ, the switching fails).
After the switching, the user name, password, and IP address of the standby iBMC are restored to
factory settings.