Table 2-14 Indicators and button on a memory board and compute module
Sy
mb
ol
Meaning Color State Description
Memory
board
button/
status
indicator
Red
and
green
● Button: triggers a hot swap of the memory board.
● Off: The memory board is not powered on.
● Steady green: The memory board is operating
properly.
● Blinking green: The memory board is in the
intermediate state of hot swap.
● Blinking red at 1 Hz: The memory board is faulty.
● Blinking red at 5 Hz: The memory board is not
securely inserted.
Priority: blinking red at 5 Hz > blinking green >
blinking red at 1 Hz > steady green > off
Memory
board
ATTN
indicator
Yello
w
● Off: The hot insertion or removal operation is
normal.
● On: The DIMM is not detected. The hot insertion or
removal operation has failed.
● Blinking: The memory board is waiting to cancel
the hot swap operation. To cancel the operation,
press the memory board button again within 5
seconds.
NOTE
This indicator is used only during the hot swap of a memory
board. The status of this indicator cannot be controlled using
the iBMC WebUI, iBMC CLI, or hardware. The meaning of this
indicator varies according to the phase. For details, see the
description of memory board hot swap in the
RH8100 V3
Server V100R003 Troubleshooting Guide
.
Memory
board
backup
indicator
Green Observe the status of this indicator during the hot
swap of a memory board.
● Off: The memory board is not a spare one.
● On: The memory board is a spare one.
Compute
module
status
indicator
Red
and
green
● Off: The compute module is not powered on.
● Steady green: The compute module is operating
properly.
● Blinking red at 1 Hz: The compute module is faulty.
● Blinking red at 5 Hz: The compute module is not
securely inserted.
shows the indicator and button on the printed circuit board (PCB) of
a memory board for the RH8100 V3.
button.
RH8100 V3 Server
User Guide
2 About the RH8100 V3
Issue 30 (2019-12-19)
Copyright © Huawei Technologies Co., Ltd.
37