Impact on the System
Powering off the RH8100 V3 interrupts the services and programs running on it.
Prerequisites
Conditions
All services have been stopped or switched to other servers.
Data
●
All data has been backed up.
●
You have determined the cabinet number and installation position for the
RH8100 V3 to be powered off.
●
You have obtained the IP address, user name, and password for the iBMC
management network port.
Tools
ESD wrist strap or ESD gloves: used to prevent ESD damage
Documents
For details about how to obtain the IP address of the iBMC management network
port and how to perform operations on iBMC, see the
Procedure
● The "power-off" mentioned here is an operation performed to change the server to the
standby state (the power indicator is steady yellow).
● After a server is powered off forcibly, wait for more than 10 seconds for the server to
power off completely. Do not power on the server again before it is completely powered
off.
● Forced power-off may damage user programs or unsaved data. Exercise caution when
performing this operation.
Power off the server to have it enter the standby state.
●
Use the KVM to shut down the server operating system (OS).
–
When the server is in single-system mode, use the KVM to shut down the
server OS.
–
When the server is in dual-system mode, use the KVM of system A to
shut down the OS of system A, and use the KVM of system B to shut
down the OS of system B.
●
When the server is in power-on state, pressing the power button on the server
front panel can power off the server gracefully.
●
Pressing the power button on the front panel to power off the server.
If the server OS is running, shut down the OS according to the onscreen instructions.