When the server is in single-system mode, pressing the primary power
button on the front panel to power off the server.
–
When the server is in dual-system mode, pressing the primary power
button on the front panel to power off system A and pressing the
secondary power button on the front panel to power off system B.
●
Hold down the power button on the front panel to power off the server.
If you use this method to power off and then on a server when a fault occurs,
some information may be missing in the fdm_log file that records
information collected through the one-click information collection function of
the management software. Avoid using this method to power off and then on
a server when a fault occurs.
–
When the server is in single-system mode, hold down the primary power
button on the front panel to power off the server.
–
When the server is in dual-system mode, hold down the primary power
button on the front panel to power off system A and hold down the
secondary power button on the front panel to power off system B.
●
In the remote management scenario, use the iBMC CLI to power off the
server.
–
When the server is in single-system mode, run the ipmcset -d
powerstate -v 0 command on the iBMC CLI to remotely power off the
server.
–
When the server is in dual-system mode, run the ipmcset -d powerstate
-v 0 command on the iBMC CLI of system A to remotely power off
system A and run this command on the iBMC CLI of system B to remotely
power off system B.
●
Use the iBMC WebUI to power off the server.
–
When the server is in single-system mode, log in to the iBMC WebUI,
choose Power on the menu bar, choose Power Control in the navigation
tree, and click Power Off and then OK to power off the server.
–
When the server is in dual-system mode, log in to the iBMC WebUI of
system A, choose Power on the menu bar, choose Power Control in the
navigation tree, click Power Off and then OK to power off system A.
Then log in to the iBMC WebUI of system B, and repeat the follow-up
operations to power off system B.
RH8100 V3 Server
User Guide
6 Powering On and Off the RH8100 V3
Issue 30 (2019-12-19)
Copyright © Huawei Technologies Co., Ltd.
306