You have powered off the RH8100 V3. For details, see
.
Data
●
You have obtained the cabinet number and chassis number of the RH8100 V3.
●
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
●
You have determined the position on the RH8100 V3 for installing a DC PSU.
Tools
●
ESD gloves
●
Packaging materials, for example, an ESD bag
●
Phillips screwdriver
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see
.
Step 2 Loosen the screw on the PSU cover and remove the cover. See step (1) in
.
Step 3 Loosen the screw on the positive and negative power cables, and remove the
cables. See step (2) in
Figure 5-135 Removing power cables
Step 4 Press the latch on the PSU, and pull out the PSU halfway while holding the
.
Step 5 Release the latch, and pull the PSU entirely out of the slot. See step (2) in
.