You have determined the position on the RH8100 V3 for installing an
indicator board interface module.
Tools
●
ESD gloves
●
Packaging materials, for example, an ESD bag
●
M3 Phillips screwdriver
Hardware
Spare indicator board interface module
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see
.
Step 2 Connect all cables to the indicator board interface module. See step (1) in
.
Step 3 Close the upper cover for the indicator board interface module. See step (2) in
.
Figure 5-33 Installing an indicator board interface module
Step 4 Insert the indicator board interface module into the slot. See step (1) in
.
Step 5 Close the latch to secure the indicator board interface module. See step (2) in
.
RH8100 V3 Server
User Guide
5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19)
Copyright © Huawei Technologies Co., Ltd.
148